10 CFR § 36.25 - Shielding.

---
identifier: "/us/cfr/t10/s36.25"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "10 CFR § 36.25 - Shielding."
title_number: 10
title_name: "Energy"
section_number: "36.25"
section_name: "Shielding."
chapter_name: "NUCLEAR REGULATORY COMMISSION"
part_number: "36"
part_name: "LICENSES AND RADIATION SAFETY REQUIREMENTS FOR IRRADIATORS"
positive_law: false
currency: "2026-04-05"
last_updated: "2026-04-05"
format_version: "1.1.0"
generator: "[email protected]"
authority: "Atomic Energy Act of 1954, secs. 81, 161, 181, 182, 183, 223, 234, 274 (42 U.S.C. 2111, 2112, 2201, 2231, 2233, 2273, 2282, 2021); Energy Reorganization Act of 1974, secs. 201, 206 (42 U.S.C. 5841, 5846); 44 U.S.C. 3504 note."
regulatory_source: "58 FR 7728, Feb. 9, 1993, unless otherwise noted."
cfr_part: "36"
---

# 36.25 Shielding.

(a) The radiation dose rate in areas that are normally occupied during operation of a panoramic irradiator may not exceed 0.02 millisievert (2 millirems) per hour at any location 30 centimeters or more from the wall of the room when the sources are exposed. The dose rate must be averaged over an area not to exceed 100 square centimeters having no linear dimension greater than 20 cm. Areas where the radiation dose rate exceeds 0.02 millisievert (2 millirems) per hour must be locked, roped off, or posted.

(b) The radiation dose at 30 centimeters over the edge of the pool of a pool irradiator may not exceed 0.02 millisievert (2 millirems) per hour when the sources are in the fully shielded position.

(c) The radiation dose rate at 1 meter from the shield of a dry-source-storage panoramic irradiator when the source is shielded may not exceed 0.02 millisievert (2 millirems) per hour and at 5 centimeters from the shield may not exceed 0.2 millisievert (20 millirems) per hour.