Skip to content
LexBuild

14 CFR § 25.1195 - Fire extinguishing systems.

---
identifier: "/us/cfr/t14/s25.1195"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "14 CFR § 25.1195 - Fire extinguishing systems."
title_number: 14
title_name: "Aeronautics and Space"
section_number: "25.1195"
section_name: "Fire extinguishing systems."
chapter_name: "FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION"
subchapter_number: "C"
subchapter_name: "AIRCRAFT"
part_number: "25"
part_name: "AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES"
positive_law: false
currency: "2026-04-05"
last_updated: "2026-04-05"
format_version: "1.1.0"
generator: "[email protected]"
authority: "49 U.S.C. 106(f), 106(g), 40113, 44701, 44702 and 44704; Pub. L. 115-254, 132 Stat 3281 (49 U.S.C. 44903 note)."
regulatory_source: "Docket No. 5066, 29 FR 18291, Dec. 24, 1964, unless otherwise noted."
cfr_part: "25"
---

# 25.1195 Fire extinguishing systems.

(a) Except for combustor, turbine, and tail pipe sections of turbine engine installations that contain lines or components carrying flammable fluids or gases for which it is shown that a fire originating in these sections can be controlled, there must be a fire extinguisher system serving each designated fire zone.

(b) The fire extinguishing system, the quantity of the extinguishing agent, the rate of discharge, and the discharge distribution must be adequate to extinguish fires. It must be shown by either actual or simulated flights tests that under critical airflow conditions in flight the discharge of the extinguishing agent in each designated fire zone specified in paragraph (a) of this section will provide an agent concentration capable of extinguishing fires in that zone and of minimizing the probability of reignition. An individual “one-shot” system may be used for auxiliary power units, fuel burning heaters, and other combustion equipment. For each other designated fire zone, two discharges must be provided each of which produces adequate agent concentration.

(c) The fire extinguishing system for a nacelle must be able to simultaneously protect each zone of the nacelle for which protection is provided.

[Doc. No. 5066, 29 FR 18291, Dec. 24, 1964, as amended by Amdt. 25-46, 43 FR 50598, Oct. 30, 1978]