30 CFR § 56.6407 - Circuit testing.
---
identifier: "/us/cfr/t30/s56.6407"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "30 CFR § 56.6407 - Circuit testing."
title_number: 30
title_name: "Mineral Resources"
section_number: "56.6407"
section_name: "Circuit testing."
chapter_name: "MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR"
subchapter_number: "K"
subchapter_name: "METAL AND NONMETAL MINE SAFETY AND HEALTH"
part_number: "56"
part_name: "SAFETY AND HEALTH STANDARDS—SURFACE METAL AND NONMETAL MINES"
positive_law: false
currency: "2026-04-05"
last_updated: "2026-04-05"
format_version: "1.1.0"
generator: "[email protected]"
authority: "30 U.S.C. 811."
regulatory_source: "50 FR 4054, Jan. 29, 1985, unless otherwise noted."
cfr_part: "56"
---
# 56.6407 Circuit testing.
A blasting galvanometer or other instrument designed for testing blasting circuits shall be used to test each of the following:
(a) Continuity of each electric or electronic detonator in the blasthole prior to stemming and connection to the blasting line.
(b) Resistance of individual series or the resistance of multiple balanced series to be connected in parallel prior to their connection to the blasting line.
(c) Continuity of blasting lines prior to the connection of electric or electronic detonator series.
(d) Total blasting circuit resistance prior to connection to the power source.
[61 FR 36795, July 12, 1996, as amended at 85 FR 2027, Jan. 14, 2020]