Skip to content
LexBuild

30 CFR § 57.6161 - Auxiliary facilities.

---
identifier: "/us/cfr/t30/s57.6161"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "30 CFR § 57.6161 - Auxiliary facilities."
title_number: 30
title_name: "Mineral Resources"
section_number: "57.6161"
section_name: "Auxiliary facilities."
chapter_name: "MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR"
subchapter_number: "K"
subchapter_name: "METAL AND NONMETAL MINE SAFETY AND HEALTH"
part_number: "57"
part_name: "SAFETY AND HEALTH STANDARDS—UNDERGROUND METAL AND NONMETAL MINES"
positive_law: false
currency: "2026-03-24"
last_updated: "2026-03-24"
format_version: "1.1.0"
generator: "[email protected]"
authority: "30 U.S.C. 811."
regulatory_source: "50 FR 4082, Jan. 29, 1985, unless otherwise noted."
cfr_part: "57"
---

# 57.6161 Auxiliary facilities.

(a) Auxiliary facilities used to store explosive material near work places shall be wooden, box-type containers equipped with covers or doors, or facilities constructed or mined-out to provide equivalent impact resistance and confinement.

(b) The auxiliary facilities shall be—

(1) Constructed of nonsparking material on the inside when used for the storage of explosives;

(2) Kept clean, suitably dry, and orderly;

(3) Kept in repair;

(4) Located out of the line of blasts so they will not be subjected to damaging shock or flyrock;

(5) Identified with warning signs or coded to indicate the contents with markings visible from any approach;

(6) Located at least 15 feet from all haulageways and electrical equipment, or placed entirely within a mined-out recess in the rib used exclusively for explosive material;

(7) Filled with no more than a one-week supply of explosive material;

(8) Separated by at least 25 feet from other facilities used to store detonators; and

(9) Kept securely locked unless all access to the mine is either locked or attended.