Skip to content
LexBuild

30 CFR § 57.6602 - Static electricity dissipation during loading.

---
identifier: "/us/cfr/t30/s57.6602"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "30 CFR § 57.6602 - Static electricity dissipation during loading."
title_number: 30
title_name: "Mineral Resources"
section_number: "57.6602"
section_name: "Static electricity dissipation during loading."
chapter_name: "MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR"
subchapter_number: "K"
subchapter_name: "METAL AND NONMETAL MINE SAFETY AND HEALTH"
part_number: "57"
part_name: "SAFETY AND HEALTH STANDARDS—UNDERGROUND METAL AND NONMETAL MINES"
positive_law: false
currency: "2026-03-24"
last_updated: "2026-03-24"
format_version: "1.1.0"
generator: "[email protected]"
authority: "30 U.S.C. 811."
regulatory_source: "50 FR 4082, Jan. 29, 1985, unless otherwise noted."
cfr_part: "57"
---

# 57.6602 Static electricity dissipation during loading.

When explosive material is loaded pneumatically into a blasthole in a manner that generates a static electricity hazard—

(a) An evaluation of the potential static electricity hazard shall be made and any hazard shall be eliminated before loading begins;

(b) The loading hose shall be of a semiconductive type, have a total of not more than 2 megohms of resistance over its entire length and not less than 1000 ohms of resistance per foot;

(c) Wire-countered hoses shall not be used;

(d) Conductive parts of the loading equipment shall be bonded and grounded and grounds shall not be made to other potential sources of extraneous electricity; and

(e) Plastic tubes shall not be used as hole liners if the hole contains an electric detonator.