Skip to content
LexBuild

30 CFR § 7.102 - Exhaust gas cooling efficiency test.

---
identifier: "/us/cfr/t30/s7.102"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "30 CFR § 7.102 - Exhaust gas cooling efficiency test."
title_number: 30
title_name: "Mineral Resources"
section_number: "7.102"
section_name: "Exhaust gas cooling efficiency test."
chapter_name: "MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR"
subchapter_number: "B"
subchapter_name: "TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS"
part_number: "7"
part_name: "TESTING BY APPLICANT OR THIRD PARTY"
positive_law: false
currency: "2026-03-24"
last_updated: "2026-03-24"
format_version: "1.1.0"
generator: "[email protected]"
authority: "30 U.S.C. 957."
regulatory_source: "53 FR 23500, June 22, 1988, unless otherwise noted."
cfr_part: "7"
---

# 7.102 Exhaust gas cooling efficiency test.

(a) *Test procedures.* (1) Follow the procedures specified in § 7.101(a).

(2) Install a temperature measuring device to measure the exhaust gas temperature at discharge from the exhaust conditioner. The temperature measuring device shall be accurate to ±4 °F (±2 °C).

(3) Determine the exhaust gas temperature at discharge from the exhaust conditioner before the exhaust gas is diluted with air.

(b) *Acceptable performance.* (1) The exhaust gas temperature at discharge from a wet exhaust conditioner before the exhaust gas is diluted with air shall not exceed 170 °F (76 °C).

(2) The exhaust gas temperature at discharge from a dry exhaust conditioner before the gas is diluted with air shall not exceed 302 °F (150 °C).