Skip to content
LexBuild

30 CFR § 7.68 - Firing line terminals test.

---
identifier: "/us/cfr/t30/s7.68"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "30 CFR § 7.68 - Firing line terminals test."
title_number: 30
title_name: "Mineral Resources"
section_number: "7.68"
section_name: "Firing line terminals test."
chapter_name: "MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR"
subchapter_number: "B"
subchapter_name: "TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS"
part_number: "7"
part_name: "TESTING BY APPLICANT OR THIRD PARTY"
positive_law: false
currency: "2026-03-24"
last_updated: "2026-03-24"
format_version: "1.1.0"
generator: "[email protected]"
authority: "30 U.S.C. 957."
regulatory_source: "53 FR 23500, June 22, 1988, unless otherwise noted."
cfr_part: "7"
---

# 7.68 Firing line terminals test.

(a) *Test procedures.* (1) The contact resistance through each firing line terminal shall be determined.

(2) A 10-pound pull shall be applied to a No. 18 gauge wire that has been connected to each firing line terminal according to the manufacturer's instructions.

(b) *Acceptable performance.* (1) The contact resistance shall not be greater than 1 ohm.

(2) The No. 18 gauge wire shall not become disconnected from either firing line terminal.