40 CFR § 405.97 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).
---identifier: "/us/cfr/t40/s405.97"source: "ecfr"legal_status: "authoritative_unofficial"title: "40 CFR § 405.97 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT)."title_number: 40title_name: "Protection of Environment"section_number: "405.97"section_name: "Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT)."chapter_name: "ENVIRONMENTAL PROTECTION AGENCY"subchapter_number: "N"subchapter_name: "EFFLUENT GUIDELINES AND STANDARDS"part_number: "405"part_name: "DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY"positive_law: falsecurrency: "2026-03-24"last_updated: "2026-03-24"format_version: "1.1.0"generator: "[email protected]"authority: "Secs. 301, 304 (b) and (c), 306 (b) and (c) and 307(c) of the Federal Water Pollution Control Act, as amended (the Act); 33 U.S.C. 1251, 1311, 1314 (b) and (c), 1316 (b) and (c), and 1317(c); 86 Stat. 816, Pub. L. 92-500; 91 Stat. 1567, Pub. L. 95-217."regulatory_source: "39 FR 18597, May 28, 1974, unless otherwise noted."cfr_part: "405"---
Identifier
/us/cfr/t40/s405.97
Currency
2026-03-24
Positive Law
No
Updated
2026-03-24
Chapter
Environmental Protection Agency
Authority
Secs. 301, 304 (b) and (c), 306 (b) and (c) and 307(c) of the Federal Water Pollution Control Act, as amended (the Act); 33 U.S.C. 1251, 1311, 1314 (b) and (c), 1316 (b) and (c), and 1317(c); 86 Stat.... Secs. 301, 304 (b) and (c), 306 (b) and (c) and 307(c) of the Federal Water Pollution Control Act, as amended (the Act); 33 U.S.C. 1251, 1311, 1314 (b) and (c), 1316 (b) and (c), and 1317(c); 86 Stat. 816, Pub. L. 92-500; 91 Stat. 1567, Pub. L. 95-217.
# 405.97 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 405.92 of this subpart for the best practicable control technology currently available (BPT).[51 FR 24996, July 9, 1986]