# 418.52 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
(a) The following limitations establish the quantity or quality of pollutants which may be discharged in process waste water from nitric acid production in which all the raw material ammonia is in the gaseous form:
[Metric units, kg/kkg of product; English units, lb/1,000 lb of product]
| | | |
| --- | --- | --- |
| Ammonia (as N) | 0.007 | 0.0007 |
| Nitrate (as N) | 0.33 | 0.044 |
(b) The following limitations establish the quantity or quality of pollutants which may be discharged in process waste water from nitric acid production in which all the raw material ammonia is in the shipped liquid form:
[Metric units, kg/kkg of product; English units, lb/1,000 lb of product]
| | | |
| --- | --- | --- |
| Ammonia (as N) | 0.08 | 0.008 |
| Nitrate (as N) | 0.33 | 0.044 |
[39 FR 12836, Apr. 8, 1974, as amended at 41 FR 2387, Jan. 16, 1976; 42 FR 16141, Mar. 25, 1977; 60 FR 33956, June 29, 1995]