---identifier: "/us/cfr/t40/s503.44"source: "ecfr"legal_status: "authoritative_unofficial"title: "40 CFR § 503.44 - Operational standard—total hydrocarbons."title_number: 40title_name: "Protection of Environment"section_number: "503.44"section_name: "Operational standard—total hydrocarbons."chapter_name: "ENVIRONMENTAL PROTECTION AGENCY"subchapter_number: "O"subchapter_name: "SEWAGE SLUDGE"part_number: "503"part_name: "STANDARDS FOR THE USE OR DISPOSAL OF SEWAGE SLUDGE"positive_law: falsecurrency: "2026-03-24"last_updated: "2026-03-24"format_version: "1.1.0"generator: "[email protected]"authority: "Sections 405 (d) and (e) of the Clean Water Act, as amended by Pub. L. 95-217, sec. 54(d), 91 Stat. 1591 (33 U.S.C. 1345 (d) and (e)); and Pub. L. 100-4, title IV, sec. 406 (a), (b), 101 Stat., 71, 72 (33 U.S.C. 1251 )."regulatory_source: "58 FR 9387, Feb. 19, 1993, unless otherwise noted."cfr_part: "503"---
Identifier
/us/cfr/t40/s503.44
Currency
2026-03-24
Positive Law
No
Updated
2026-03-24
Chapter
Environmental Protection Agency
Authority
Sections 405 (d) and (e) of the Clean Water Act, as amended by Pub. L. 95-217, sec. 54(d), 91 Stat. 1591 (33 U.S.C. 1345 (d) and (e)); and Pub. L. 100-4, title IV, sec. 406 (a), (b), 101 Stat., 71, 72... Sections 405 (d) and (e) of the Clean Water Act, as amended by Pub. L. 95-217, sec. 54(d), 91 Stat. 1591 (33 U.S.C. 1345 (d) and (e)); and Pub. L. 100-4, title IV, sec. 406 (a), (b), 101 Stat., 71, 72 (33 U.S.C. 1251 ).
# 503.44 Operational standard—total hydrocarbons.(a) The total hydrocarbons concentration in the exit gas from a sewage sludge incinerator shall be corrected for zero percent moisture by multiplying the measured total hydrocarbons concentration by the correction factor calculated using equation (7).Where:X = decimal fraction of the percent moisture in the sewage sludge incinerator exit gas in hundredths.(b) The total hydrocarbons concentration in the exit gas from a sewage sludge incinerator shall be corrected to seven percent oxygen by multiplying the measured total hydrocarbons concentration by the correction factor calculated using equation (8).Where:Y = Percent oxygen concentration in the sewage sludge incinerator stack exit gas (dry volume/dry volume).(c) The monthly average concentration for total hydrocarbons in the exit gas from a sewage sludge incinerator stack, corrected for zero percent moisture using the correction factor from equation (7) and to seven percent oxygen using the correction factor from equation (8), shall not exceed 100 parts per million on a volumetric basis when measured using the instrument required by § 503.45(a).