# 60.344 Test methods and procedures.
(a) In conducting the performance tests required in § 60.8, the owner or operator shall use as reference methods and procedures the test methods in appendix A of this part or other methods and procedures as specified in this section, except as provided in § 60.8(b).
(b) The owner or operator shall determine compliance with the particulate matter standards in § 60.342(a) as follows:
(1) The emission rate (E) of particulate matter shall be computed for each run using the following equation:
E = (c<sub>s</sub> Q<sub>sd</sub>)/PK)
where:
E = emission rate of particulate matter, kg/Mg (1b/ton) of stone feed.
c<sub>s</sub> = concentration of particulate matter, g/dscm (gr/dscf).
Q<sub>sd</sub> = volumetric flow rate of effluent gas, dscm/hr (dscf/hr).
P = stone feed rate, Mg/hr (ton/hr).
K = conversion factor, 1000 g/kg (7000 gr/lb).
(2) Method 5 shall be used at negative-pressure fabric filters and other types of control devices and Method 5D shall be used at positive-pressure fabric filters to determine the particulate matter concentration (c<sub>s</sub>) and the volumetric flow rate (Q<sub>sd</sub>) of the effluent gas. The sampling time and sample volume for each run shall be at least 60 minutes and 0.90 dscm (31.8 dscf).
(3) The monitoring device of § 60.343(d) shall be used to determine the stone feed rate (P) for each run.
(4) Method 9 and the procedures in § 60.11 shall be used to determine opacity.
(c) During the particulate matter run, the owner or operator shall use the monitoring devices in § 60.343(c)(1) and (2) to determine the average pressure loss of the gas stream through the scrubber and the average scrubbing liquid supply pressure.
[54 FR 6675, Feb. 14, 1989, as amended at 65 FR 61760, Oct. 17, 2000]