Skip to content
LexBuild

40 CFR § 63.5890 - How do I calculate an organic HAP emissions factor to demonstrate compliance for continuous lamination/casting operations?

---
identifier: "/us/cfr/t40/s63.5890"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "40 CFR § 63.5890 - How do I calculate an organic HAP emissions factor to demonstrate compliance for continuous lamination/casting operations?"
title_number: 40
title_name: "Protection of Environment"
section_number: "63.5890"
section_name: "How do I calculate an organic HAP emissions factor to demonstrate compliance for continuous lamination/casting operations?"
chapter_name: "ENVIRONMENTAL PROTECTION AGENCY"
subchapter_number: "C"
subchapter_name: "AIR PROGRAMS"
part_number: "63"
part_name: "NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES"
positive_law: false
currency: "2026-03-24"
last_updated: "2026-03-24"
format_version: "1.1.0"
generator: "[email protected]"
authority: "42 U.S.C. 7401"
regulatory_source: "57 FR 61992, Dec. 29, 1992, unless otherwise noted."
cfr_part: "63"
---

# 63.5890 How do I calculate an organic HAP emissions factor to demonstrate compliance for continuous lamination/casting operations?

(a) *Compliant line option.* Use Equation 1 of this section to calculate an organic HAP emissions factor in lbs/ton.

Where:

E = HAP emissions factor in lbs/ton of resin and gel coat

WAE<sub>u</sub> = uncontrolled wet-out area organic HAP emissions, lbs per year

WAE<sub>c</sub> = controlled wet-out area organic HAP emissions, lbs per year

O<sub>u</sub> = uncontrolled oven organic HAP emissions, lbs per year

O<sub>c</sub> = controlled oven organic HAP emissions, lbs per year

R = total usage of neat resin plus, tpy

G = total usage of neat gel coat plus, tpy

(b) *Averaging option.* Use Equation 2 of this section to demonstrate compliance.

Where:

E = HAP emissions factor in lbs/ton of resin and gel coat

WAE<sub>ui</sub> = uncontrolled organic HAP emissions from wet-out area i, lbs per year

WAE<sub>ci</sub> = controlled organic HAP emissions from wet-out area i, lbs per year

O<sub>uj</sub> = uncontrolled organic HAP emissions from oven j, lbs per year

O<sub>cj</sub> = controlled organic HAP emissions from oven j, lbs per year

i = number of wet-out areas

j = number of ovens

m = number of wet-out areas uncontrolled

n = number of ovens uncontrolled

o = number of wet-out areas controlled

p = number of ovens controlled

R = total usage of neat resin plus, tpy

G = total usage of neat gel coat plus, tpy

(c) *Combination option.* Use Equations 1 and 2 of this section, as applicable, to demonstrate compliance.