Skip to content
LexBuild

40 CFR § 761.350 - Subsampling from composite samples.

---
identifier: "/us/cfr/t40/s761.350"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "40 CFR § 761.350 - Subsampling from composite samples."
title_number: 40
title_name: "Protection of Environment"
section_number: "761.350"
section_name: "Subsampling from composite samples."
chapter_name: "ENVIRONMENTAL PROTECTION AGENCY"
subchapter_number: "R"
subchapter_name: "TOXIC SUBSTANCES CONTROL ACT"
part_number: "761"
part_name: "POLYCHLORINATED BIPHENYLS (PCBs) MANUFACTURING, PROCESSING, DISTRIBUTION IN COMMERCE, AND USE PROHIBITIONS"
positive_law: false
currency: "2026-03-24"
last_updated: "2026-03-24"
format_version: "1.1.0"
generator: "[email protected]"
authority: "15 U.S.C. 2605, 2607, 2611, 2614, and 2616 and 42 U.S.C. 6939g."
regulatory_source: "43 FR 7156, Feb. 17, 1978, unless otherwise noted."
cfr_part: "761"
---

# 761.350 Subsampling from composite samples.

(a) *Preparing the composite.* Composite the samples (eight from a flattened pile; eight or more from a conical pile; eight from waste that is continuously generated) and select a 19-liter subsample for shipment to the chemical extraction and analysis laboratory for further subsampling. There are two options for the preparation of the composite:

(1) *Option one.* Place all of the contents of all 19-liter samples that you collected into a 209 liter (55 gallon) drum or similar sized, cylinder-shaped container. Completely close the container, and roll it 10 or more complete revolutions to mix the contents.

(2) *Option two.* Add the 19-liter samples one at a time to a 209 liter (55 gallon) drum. Between the addition of each 19-liter sample, stir the composite using a broom handle or similar long, narrow, sturdy rod that reaches the bottom of the container. Stir the mixture for a minimum of 10 complete revolutions of the stirring instrument around the container at a distance approximately half way between the outside and center of the container.

(b) *Selecting a 19-liter subsample from the composite.* Once the composite is mixed, pour the mixture of waste out on a plastic sheet and either divide it into 19-liter size piles or make one large pile.

(1) From 19-liter sized piles, use a random number generator or random number table to select one of the piles.

(2) From one large pile, flatten the pile to a depth of 30 cm and divide it into 4 quarters of equal size. Use a random number generator or random number table to select one quarter of the pile. Further divide the selected quarter pile into 19-liter portions and use a random number generator or random number table to select one 19-liter portion. A square having a 25 cm side or a circle having a diameter of approximately 28.5 cm when projected downwards 30 cm equals approximately 19 liters.

(c) *Transferring the sample to the analytical laboratory.* Place the selected 19-liter subsample in a container, approved for shipment of the sample, to the chemical extraction and analysis laboratory, for the next step in sample selection in accordance with § 761.353.