# 98.451 Reporting threshold.

You must report GHG emissions under this subpart if your facility contains an electrical equipment manufacturing or refurbishing process and the facility meets the requirements of § 98.2(a)(2). To calculate total annual GHG emissions for comparison to the 25,000 metric ton CO<sub>2</sub>e per year emission threshold in § 98.2(a)(2), follow the requirements of § 98.2(b), with one exception. Instead of following the requirement of § 98.453 to calculate emissions from electrical equipment manufacture or refurbishment, you must calculate emissions of each fluorinated GHG that is a component of a reportable insulating gas and then sum the emissions of each fluorinated GHG resulting from manufacturing and refurbishing electrical equipment using equation SS-1 to this section.

Where:

E = Annual production process emissions for threshold applicability purposes (metric tons CO<sub>2</sub>e).

P<sub>j</sub> = Total annual purchases of reportable insulating gas j (lbs).

GHG<sub>i,w</sub> = The weight fraction of fluorinated GHG i in reportable insulating gas j if reportable insulating gas j is a gas mixture. If not a mixture, use 1.

GWP<sub>i</sub> = Gas-appropriate GWP as provided in table A-1 to subpart A of this part.

EF = Emission factor for electrical transmission and distribution equipment (lbs emitted/lbs purchased). For all gases, use an emission factor of 0.1.

i = Fluorinated GHG contained in the electrical transmission and distribution equipment.

0.000453592 = Conversion factor from lbs to metric tons.