Skip to content
LexBuild

42 CFR § 84.160 - Man test for gases and vapors; Type A and Type AE respirators; test requirements.

---
identifier: "/us/cfr/t42/s84.160"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "42 CFR § 84.160 - Man test for gases and vapors; Type A and Type AE respirators; test requirements."
title_number: 42
title_name: "Public Health"
section_number: "84.160"
section_name: "Man test for gases and vapors; Type A and Type AE respirators; test requirements."
chapter_name: "PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES"
subchapter_number: "G"
subchapter_name: "OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES"
part_number: "84"
part_name: "APPROVAL OF RESPIRATORY PROTECTIVE DEVICES"
positive_law: false
currency: "2026-04-05"
last_updated: "2026-04-05"
format_version: "1.1.0"
generator: "[email protected]"
authority: "29 U.S.C. 651  30 U.S.C. 3, 5, 7, 811, 842(h), 844."
regulatory_source: "60 FR 30355, June 8, 1995, unless otherwise noted."
cfr_part: "84"
---

# 84.160 Man test for gases and vapors; Type A and Type AE respirators; test requirements.

(a) The completely assembled respirator will be worn in a chamber containing 0.1 ±0.025 percent isoamyl acetate vapor, and the blower, the intake of the hose, and not more than 25 percent of the hose length will be located in isoamyl acetate-free air.

(b) The man in the isoamyl acetate atmosphere will draw his inspired air through the hose, connections, and all parts of the air device by means of his lungs alone (blower not operating).

(c) The 10-minute work test will be repeated with the blower in operation at any practical speed up to 50 revolutions of the crank per minute.