Skip to content
LexBuild

46 CFR § 105.13 - Electrical fittings and fixtures.

---
identifier: "/us/cfr/t46/s105.13"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "46 CFR § 105.13 - Electrical fittings and fixtures."
title_number: 46
title_name: "Shipping"
section_number: "105.13"
section_name: "Electrical fittings and fixtures."
chapter_name: "COAST GUARD, DEPARTMENT OF HOMELAND SECURITY"
subchapter_number: "I"
subchapter_name: "CARGO AND MISCELLANEOUS VESSELS"
part_number: "105"
part_name: "COMMERCIAL FISHING VESSELS DISPENSING PETROLEUM PRODUCTS"
positive_law: false
currency: "2026-03-24"
last_updated: "2026-03-24"
format_version: "1.1.0"
generator: "[email protected]"
authority: "6 U.S.C. 468(b); 33 U.S.C. 1321(j); 46 U.S.C. 2103, 3306, 3703, 4502; E.O. 12777, sec. 2(d)(2) and (f), 56 FR 54757, 3 CFR, 1991 Comp., p. 351; DHS Delegation No. 00170.1, Revision No. 01.4."
regulatory_source: "81 FR 13283, Mar. 14, 2016, unless otherwise noted."
cfr_part: "105"
---

# 105.13 Electrical fittings and fixtures.

(a) In compartments or areas containing tanks or pumps handling petroleum products other than Grade E products, no electrical fittings, fixtures, or equipment may be installed or used unless approved for a Class I, Group D hazardous location and labeled as such by UL or another recognized laboratory.

(b) All electrical equipment, fixtures, and fittings located within 10 feet of a vent outlet or a dispensing outlet must be explosion-proof and labeled as such by UL or another recognized laboratory, as suitable for Class I, Group D atmospheres.

(c) All electrical equipment must be grounded to the vessel's common ground.

(d) Tanks, containers, and associated piping systems in use prior to December 1, 1969, on a vessel the construction of which was contracted for before May 31, 1976, are exempt from the requirements of this section provided they are maintained in a condition that the Officer in Charge, Marine Inspection, finds satisfactory, and provided that major repairs or replacement of exempted equipment and systems is in accordance with this part.