Skip to content
LexBuild

46 CFR § 116.430 - Insulation other than for structural fire protection.

---
identifier: "/us/cfr/t46/s116.430"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "46 CFR § 116.430 - Insulation other than for structural fire protection."
title_number: 46
title_name: "Shipping"
section_number: "116.430"
section_name: "Insulation other than for structural fire protection."
chapter_name: "COAST GUARD, DEPARTMENT OF HOMELAND SECURITY"
subchapter_number: "K"
subchapter_name: "SMALL PASSENGER VESSELS CARRYING MORE THAN 150 PASSENGERS OR WITH OVERNIGHT ACCOMMODATIONS FOR MORE THAN 49 PASSENGERS"
part_number: "116"
part_name: "CONSTRUCTION AND ARRANGEMENT"
positive_law: false
currency: "2026-04-05"
last_updated: "2026-04-05"
format_version: "1.1.0"
generator: "[email protected]"
authority: "46 U.S.C. 2103, 3306; E.O. 12234, 45 FR 58801, 3 CFR, 1980 Comp., p. 277, DHS Delegation 00170.1, Revision No. 01.4."
regulatory_source: "CGD 85-080, 61 FR 900, Jan. 10, 1996, unless otherwise noted."
cfr_part: "116"
---

# 116.430 Insulation other than for structural fire protection.

(a) Combustible insulation may be used for pipe and machinery covering or lagging within a machinery space, or used in an individual refrigerator box if the refrigerator box was purchased with the insulation already installed.

(b) Except as allowed by paragraph (a) of this section, any insulation installed for purposes other than structural fire protection and all material incidental to its installation must be noncombustible or approved under § 164.009 in subchapter Q of this chapter. Surfacing material applied to such insulation must be noncombustible or may meet the requirements of § 116.422(c) of this part.