Skip to content
LexBuild

46 CFR § 116.600 - Ventilation of enclosed and partially enclosed spaces.

---
identifier: "/us/cfr/t46/s116.600"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "46 CFR § 116.600 - Ventilation of enclosed and partially enclosed spaces."
title_number: 46
title_name: "Shipping"
section_number: "116.600"
section_name: "Ventilation of enclosed and partially enclosed spaces."
chapter_name: "COAST GUARD, DEPARTMENT OF HOMELAND SECURITY"
subchapter_number: "K"
subchapter_name: "SMALL PASSENGER VESSELS CARRYING MORE THAN 150 PASSENGERS OR WITH OVERNIGHT ACCOMMODATIONS FOR MORE THAN 49 PASSENGERS"
part_number: "116"
part_name: "CONSTRUCTION AND ARRANGEMENT"
positive_law: false
currency: "2026-03-24"
last_updated: "2026-03-24"
format_version: "1.1.0"
generator: "[email protected]"
authority: "46 U.S.C. 2103, 3306; E.O. 12234, 45 FR 58801, 3 CFR, 1980 Comp., p. 277, DHS Delegation 00170.1, Revision No. 01.4."
regulatory_source: "CGD 85-080, 61 FR 900, Jan. 10, 1996, unless otherwise noted."
cfr_part: "116"
---

# 116.600 Ventilation of enclosed and partially enclosed spaces.

(a) An enclosed or partially enclosed space within a vessel must be adequately ventilated in a manner suitable for the purpose of the space.

(b) A power ventilation system must be capable of being shut down from the pilot house.

(c) An enclosed passenger or crew accommodation space and any other space occupied by a crew member on a regular basis must be ventilated by a power ventilation system unless natural ventilation in all ordinary weather conditions is satisfactory to the OCMI.

(d) An exhaust duct over a frying vat or a grill must be at least 11 U.S. Standard Gauge (USSG) steel.

[CGD 85-080, 61 FR 900, Jan. 10, 1996, as amended at 62 FR 51350, Sept. 30, 1997]