Skip to content
LexBuild

46 CFR § 130.230 - Protection from refrigerants.

---
identifier: "/us/cfr/t46/s130.230"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "46 CFR § 130.230 - Protection from refrigerants."
title_number: 46
title_name: "Shipping"
section_number: "130.230"
section_name: "Protection from refrigerants."
chapter_name: "COAST GUARD, DEPARTMENT OF HOMELAND SECURITY"
subchapter_number: "L"
subchapter_name: "OFFSHORE SUPPLY VESSELS"
part_number: "130"
part_name: "VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS"
positive_law: false
currency: "2026-04-05"
last_updated: "2026-04-05"
format_version: "1.1.0"
generator: "[email protected]"
authority: "46 U.S.C. 3306; Department of Homeland Security Delegation No. 0170.1. Sections 130.140 and 130.400 also issued under sec. 617, Pub. L. 111-281, 124 Stat. 2905."
regulatory_source: "CGD 82-004 and CGD 86-074, 62 FR 49337, Sept. 19, 1997, unless otherwise noted."
cfr_part: "130"
---

# 130.230 Protection from refrigerants.

(a) For each refrigeration system that exceeds 0.6 cubic meters (20 cubic feet) of storage capacity if using ammonia or other hazardous gas, or exceeds 28.3 cubic meters (1,000 cubic feet) of storage capacity if using a fluorocarbon, as a refrigerant, there must be available one pressure-demand, open-circuit, self-contained breathing apparatus, approved by the National Institute for Occupational Safety and Health (NIOSH) and having at a minimum a 30-minute air supply, and a full facepiece.

(b) Each self-contained breathing apparatus must be stowed convenient to, but outside, the space containing the refrigeration equipment.

(c) A complete recharge in the form of a spare charge must be carried for each self-contained breathing apparatus. The spare charge must be stowed with the equipment it is to reactivate.

(d) The self-contained breathing apparatus in a fireman's outfit, if fitted, complies with this section.