Skip to content
LexBuild

46 CFR § 142.225 - Storage of flammable or combustible products.

---
identifier: "/us/cfr/t46/s142.225"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "46 CFR § 142.225 - Storage of flammable or combustible products."
title_number: 46
title_name: "Shipping"
section_number: "142.225"
section_name: "Storage of flammable or combustible products."
chapter_name: "COAST GUARD, DEPARTMENT OF HOMELAND SECURITY"
subchapter_number: "M"
subchapter_name: "TOWING VESSELS"
part_number: "142"
part_name: "FIRE PROTECTION"
positive_law: false
currency: "2026-03-24"
last_updated: "2026-03-24"
format_version: "1.1.0"
generator: "[email protected]"
authority: "46 U.S.C. 3103, 3301, 3306, 3308, 3316, 8104, 8904; 33 CFR 1.05; DHS Delegation 0170.1."
regulatory_source: "USCG-2006-24412, 81 FR 40101, June 20, 2016, unless otherwise noted."
cfr_part: "142"
---

# 142.225 Storage of flammable or combustible products.

(a) Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use.

(b) If a storage room is provided, it may be any room or compartment that is free of ignition sources.

(c) If a dedicated storage cabinet is provided it must be secured to the vessel so that it does not move and must be either:

(1) A flammable liquid storage cabinet that satisfies UL 1275 (incorporated by reference, see § 136.112 of this subchapter); or

(2) A flammable liquid storage cabinet that satisfies FM Approvals Standard 6050 (incorporated by reference, see § 136.112 of this subchapter); or

(3) Another suitable steel container that provides an equivalent level of protection.

(d) A 40-B portable fire extinguisher must be located near the storage room or cabinet. This is in addition to the portable fire extinguishers required by tables 142.230(a) and 142.230(b) of this part.

[USCG-2006-24412, 81 FR 40101, June 20, 2016, as amended by USCG-2017-1060, 83 FR 8180, Feb. 26, 2018]