---identifier: "/us/cfr/t46/s153.314"source: "ecfr"legal_status: "authoritative_unofficial"title: "46 CFR § 153.314 - Ventilation of spaces not usually occupied."title_number: 46title_name: "Shipping"section_number: "153.314"section_name: "Ventilation of spaces not usually occupied."chapter_name: "COAST GUARD, DEPARTMENT OF HOMELAND SECURITY"subchapter_number: "O"subchapter_name: "CERTAIN BULK DANGEROUS CARGOES"part_number: "153"part_name: "SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS"positive_law: falsecurrency: "2026-04-05"last_updated: "2026-04-05"format_version: "1.1.0"generator: "[email protected]"authority: "46 U.S.C. 3703; Department of Homeland Security Delegation No. 0170.1. Section 153.40 issued under 49 U.S.C. 5103. Sections 153.470 through 153.491, 153.1100 through 153.1132, and 153.1600 through 153.1608 also issued under 33 U.S.C. 1903 (b)."regulatory_source: "CGD 73-96, 42 FR 49027, Sept. 26, 1977, unless otherwise noted."cfr_part: "153"---
Identifier
/us/cfr/t46/s153.314
Currency
2026-04-05
Positive Law
No
Updated
2026-04-05
Chapter
Coast Guard, Department of Homeland Security
Authority
46 U.S.C. 3703; Department of Homeland Security Delegation No. 0170.1. Section 153.40 issued under 49 U.S.C. 5103. Sections 153.470 through 153.491, 153.1100 through 153.1132, and 153.1600 through 153... 46 U.S.C. 3703; Department of Homeland Security Delegation No. 0170.1. Section 153.40 issued under 49 U.S.C. 5103. Sections 153.470 through 153.491, 153.1100 through 153.1132, and 153.1600 through 153.1608 also issued under 33 U.S.C. 1903 (b).
# 153.314 Ventilation of spaces not usually occupied.(a) Each tankship must have portable ventilation equipment that fits the mount required in paragraph (b)(1) of this section.(b) Each enclosed space within the cargo area that does not have a permanent ventilation system meeting § 153.312 must have:(1) A mount for the portable mechanical ventilation equipment required by this section; and(2) Either permanent ventilation ductwork connected to the mount and arranged to supply air to the extremities of the space; or(3) An attachment for temporary ductwork at the mount with enough ductway in the ventilated space and temporary ductwork stowed aboard the vessel to supply air to the extremities of the space.[CGD 73-96, 42 FR 49027, Sept. 26, 1977, as amended by CGD 78-128, 47 FR 21208, May 17, 1982]