---identifier: "/us/cfr/t46/s153.409"source: "ecfr"legal_status: "authoritative_unofficial"title: "46 CFR § 153.409 - High level alarms."title_number: 46title_name: "Shipping"section_number: "153.409"section_name: "High level alarms."chapter_name: "COAST GUARD, DEPARTMENT OF HOMELAND SECURITY"subchapter_number: "O"subchapter_name: "CERTAIN BULK DANGEROUS CARGOES"part_number: "153"part_name: "SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS"positive_law: falsecurrency: "2026-04-05"last_updated: "2026-04-05"format_version: "1.1.0"generator: "[email protected]"authority: "46 U.S.C. 3703; Department of Homeland Security Delegation No. 0170.1. Section 153.40 issued under 49 U.S.C. 5103. Sections 153.470 through 153.491, 153.1100 through 153.1132, and 153.1600 through 153.1608 also issued under 33 U.S.C. 1903 (b)."regulatory_source: "CGD 73-96, 42 FR 49027, Sept. 26, 1977, unless otherwise noted."cfr_part: "153"---
Identifier
/us/cfr/t46/s153.409
Currency
2026-04-05
Positive Law
No
Updated
2026-04-05
Chapter
Coast Guard, Department of Homeland Security
Authority
46 U.S.C. 3703; Department of Homeland Security Delegation No. 0170.1. Section 153.40 issued under 49 U.S.C. 5103. Sections 153.470 through 153.491, 153.1100 through 153.1132, and 153.1600 through 153... 46 U.S.C. 3703; Department of Homeland Security Delegation No. 0170.1. Section 153.40 issued under 49 U.S.C. 5103. Sections 153.470 through 153.491, 153.1100 through 153.1132, and 153.1600 through 153.1608 also issued under 33 U.S.C. 1903 (b).
# 153.409 High level alarms.When Table 1 refers to this section or requires a cargo to have a closed gauging system, the cargo's containment system must have a high level alarm:(a) That gives an audible and visual alarm before the tank fills to 97 percent of its capacity;(b) That can be seen and heard where cargo transfer is controlled and on the open deck;(c) Whose operation can be checked prior to each loading; and(d) That must be marked as described in § 153.408(c)(6) with the legend “HIGH LEVEL ALARM.”[CGD 78-128, 47 FR 21209, May 17, 1982; 47 FR 27293, June 24, 1982]