# 153.470 System for discharge of NLS residue to the sea: Categories A, B, C, and D.
Unless waived under § 153.491, each ship that discharges Category A, B, or C NLS residue, or Category D NLS residue not diluted to
1/10th of its original concentration, into the sea under §§ 153.1126 and 153.1128 must have an NLS residue discharge system meeting the following:
(a) *Minimum diameter of an NLS residue discharge outlet.* The outlet of each NLS residue discharge system must have a diameter at least as great as that given by the following formula:
where:
D = Minimum diameter of the discharge outlet in meters.
Q<sub>d</sub> = Maximum rate in cubic meters per hour at which the ship operator wishes to discharge slops (note: Q<sub>d</sub> affects the discharge rate allowed under § 153.1126(b)(2)).
L = Distance from the forward perpendicular to the discharge outlet in meters.
φ = The acute angle between a perpendicular to the shell plating at the discharge location and the direction of the average velocity of the discharged liquid.
(b) *Location of an NLS residue discharge outlet.* Each NLS residue discharge outlet must be located—
(1) At the turn of the bilge beneath the cargo area; and
(2) Where the discharge from the outlet is not drawn into the ship's seawater intakes.
(c) *Location of dual NLS residue discharge outlets.* If the value of 6.45 for K is used in § 153.1126(b)(2), the NLS residue discharge system must have two outlets located on opposite sides of the ship.
[CGD 81-101, 52 FR 7781, Mar. 12, 1987, as amended by CGD 81-101, 53 FR 28974, Aug. 1, 1988 and 54 FR 12629, Mar. 28, 1989; CGD 95-028, 62 FR 51209, Sept. 30, 1997]