Skip to content
LexBuild

46 CFR § 154.1005 - Equipment approval.

---
identifier: "/us/cfr/t46/s154.1005"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "46 CFR § 154.1005 - Equipment approval."
title_number: 46
title_name: "Shipping"
section_number: "154.1005"
section_name: "Equipment approval."
chapter_name: "COAST GUARD, DEPARTMENT OF HOMELAND SECURITY"
subchapter_number: "O"
subchapter_name: "CERTAIN BULK DANGEROUS CARGOES"
part_number: "154"
part_name: "SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES"
positive_law: false
currency: "2026-04-05"
last_updated: "2026-04-05"
format_version: "1.1.0"
generator: "[email protected]"
authority: "46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1."
regulatory_source: "CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted."
cfr_part: "154"
---

# 154.1005 Equipment approval.

(a) Electrical equipment that is required to be intrinsically safe or explosion proof under § 154.1010 must be specially approved by the Commandant or listed as intrinsically safe or explosion proof by an independent laboratory that is specially approved by the Commandant (CG-OES), for Class I Division I locations and the Group that is specified in Table 4 for the cargo carried.

(b) Each submerged cargo pump motor installation must be specially approved by the Commandant (CG-OES).

(c) Electrical equipment that must be intrinsically safe to meet § 154.1010 must meet the definition in § 110.15-100(i) of this chapter.

(d) Electrical equipment that must be explosion proof to meet § 154.1010 must meet § 110.15-65(e) of this chapter.

[CGD 74-289, 44 FR 26009, May 3, 1979, as amended by CGD 82-063b, 48 FR 4782, Feb. 3, 1983]