46 CFR § 154.520 - Piping calculations.
---
identifier: "/us/cfr/t46/s154.520"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "46 CFR § 154.520 - Piping calculations."
title_number: 46
title_name: "Shipping"
section_number: "154.520"
section_name: "Piping calculations."
chapter_name: "COAST GUARD, DEPARTMENT OF HOMELAND SECURITY"
subchapter_number: "O"
subchapter_name: "CERTAIN BULK DANGEROUS CARGOES"
part_number: "154"
part_name: "SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES"
positive_law: false
currency: "2026-04-05"
last_updated: "2026-04-05"
format_version: "1.1.0"
generator: "[email protected]"
authority: "46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1."
regulatory_source: "CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted."
cfr_part: "154"
---
# 154.520 Piping calculations.
A piping system must be designed to meet the allowable stress values under § 56.07-10 of this chapter and, if the design temperature is −110 °C (−166 °F) or lower, the stress analysis must be specially approved by the Commandant (CG-ENG) and must include:
(a) Pipe weight loads;
(b) Acceleration loads;
(c) Internal pressure loads;
(d) Thermal loads; and
(e) Loads from the hull.
[CGD 74-289, 44 FR 26009, May 3, 1979, as amended by CGD 82-063b, 48 FR 4782, Feb. 3, 1983]