Skip to content
LexBuild

46 CFR § 182.470 - Ventilation of spaces containing diesel fuel tanks.

---
identifier: "/us/cfr/t46/s182.470"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "46 CFR § 182.470 - Ventilation of spaces containing diesel fuel tanks."
title_number: 46
title_name: "Shipping"
section_number: "182.470"
section_name: "Ventilation of spaces containing diesel fuel tanks."
chapter_name: "COAST GUARD, DEPARTMENT OF HOMELAND SECURITY"
subchapter_number: "T"
subchapter_name: "SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS)"
part_number: "182"
part_name: "MACHINERY INSTALLATION"
positive_law: false
currency: "2026-03-24"
last_updated: "2026-03-24"
format_version: "1.1.0"
generator: "[email protected]"
authority: "46 U.S.C. 3306; E.O. 12234, 45 FR 58801, 3 CFR, 1980 Comp., p. 277; DHS Delegation No. 00170.1, Revision No. 01.4."
regulatory_source: "CGD 85-080, 61 FR 986, Jan. 10, 1996, unless otherwise noted."
cfr_part: "182"
---

# 182.470 Ventilation of spaces containing diesel fuel tanks.

(a) Unless provided with ventilation that complies with § 182.465, a space containing a diesel fuel tank and no machinery must meet the requirements of this section.

(1) A space of 14 cubic meters (500 cubic feet) or more in volume must have a gooseneck vent of not less than 65 millimeters (2.5 inches) in diameter.

(2) A space of less than 14 cubic meters (500 cubic feet) in volume must have a gooseneck vent of not less than 40 millimeters (1.5 inches) in diameter.

(b) Vent openings may not be located adjacent to possible sources of vapor ignition.

(c) A vessel of not more than 19.8 meters (65 feet) in length, carrying not more than 12 passengers, with ventilation installations in accordance with ABYC H-32 (incorporated by reference; see 46 CFR 175.600) will be considered as meeting the requirements of this section.

[CGD 85-080, 61 FR 986, Jan. 10, 1996, as amended by USCG-2003-16630, 73 FR 65209, Oct. 31, 2008]