Skip to content
LexBuild

46 CFR § 182.530 - Bilge high level alarms.

---
identifier: "/us/cfr/t46/s182.530"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "46 CFR § 182.530 - Bilge high level alarms."
title_number: 46
title_name: "Shipping"
section_number: "182.530"
section_name: "Bilge high level alarms."
chapter_name: "COAST GUARD, DEPARTMENT OF HOMELAND SECURITY"
subchapter_number: "T"
subchapter_name: "SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS)"
part_number: "182"
part_name: "MACHINERY INSTALLATION"
positive_law: false
currency: "2026-03-24"
last_updated: "2026-03-24"
format_version: "1.1.0"
generator: "[email protected]"
authority: "46 U.S.C. 3306; E.O. 12234, 45 FR 58801, 3 CFR, 1980 Comp., p. 277; DHS Delegation No. 00170.1, Revision No. 01.4."
regulatory_source: "CGD 85-080, 61 FR 986, Jan. 10, 1996, unless otherwise noted."
cfr_part: "182"
---

# 182.530 Bilge high level alarms.

(a) On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces:

(1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette;

(2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space; and

(3) A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck.

(b) Vessels constructed of wood must, in addition to paragraph (a), provide bilge level alarms in all watertight compartments except small buoyancy chambers.

(c) A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating.