Skip to content
LexBuild

46 CFR § 32.56-60 - Ventilation ducts—T/ALL.

---
identifier: "/us/cfr/t46/s32.56-60"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "46 CFR § 32.56-60 - Ventilation ducts—T/ALL."
title_number: 46
title_name: "Shipping"
section_number: "32.56-60"
section_name: "Ventilation ducts—T/ALL."
chapter_name: "COAST GUARD, DEPARTMENT OF HOMELAND SECURITY"
subchapter_number: "D"
subchapter_name: "TANK VESSELS"
part_number: "32"
part_name: "SPECIAL EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS"
positive_law: false
currency: "2026-03-24"
last_updated: "2026-03-24"
format_version: "1.1.0"
generator: "[email protected]"
authority: "46 U.S.C. 2103, 3306, 3703, 3719; E.O. 12234, 45 FR 58801, 3 CFR, 1980 Comp., p. 277; DHS Delegation No. 00170.1, Revision No. 01.4; Subpart 32.59 also issued under the authority of Sec. 4109, Pub. L. 101-380, 104 Stat. 515."
regulatory_source: "CGFR 65-50, 30 FR 16671, Dec. 30, 1965, unless otherwise noted."
cfr_part: "32"
---

# 32.56-60 Ventilation ducts—T/ALL.

(a) Each duct for ventilation of Category A machinery spaces that passes through accommodation, service, or control spaces must be:

(1) Constructed of steel and insulated to “A-60” Class; or

(2) Constructed of steel, fitted with an automatic fire damper at each boundary where it enters and leaves the Category A machinery space, and insulated to “A-60” Class for a distance of 5 meters (16.4 feet) beyond each machinery space boundary.

(b) Each duct for ventilation of accommodation, service, and control spaces that passes through Category A machinery spaces must be constructed of steel and be fitted with an automatic fire damper at each Category A machinery space boundary.