# 56.50-45 Circulating pumps.

(a) A main circulating pump and emergency means for circulating water through the main condenser must be provided. The emergency means may consist of a connection from an independent power pump fitted between the main circulating pump and the condenser.

(b) Independent sea suctions must be provided for the main circulating and the emergency circulating pumps.