Skip to content
LexBuild

46 CFR § 64.79 - Inspection of pressure and vacuum relief device.

---
identifier: "/us/cfr/t46/s64.79"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "46 CFR § 64.79 - Inspection of pressure and vacuum relief device."
title_number: 46
title_name: "Shipping"
section_number: "64.79"
section_name: "Inspection of pressure and vacuum relief device."
chapter_name: "COAST GUARD, DEPARTMENT OF HOMELAND SECURITY"
subchapter_number: "F"
subchapter_name: "MARINE ENGINEERING"
part_number: "64"
part_name: "MARINE PORTABLE TANKS AND CARGO HANDLING SYSTEMS"
positive_law: false
currency: "2026-03-24"
last_updated: "2026-03-24"
format_version: "1.1.0"
generator: "[email protected]"
authority: "46 U.S.C. 3306, 3703; 49 U.S.C. App. 1804; Department of Homeland Security Delegation No. 00170.1, Revision No. 01.3."
regulatory_source: "CGD 73-172, 39 FR 22950, June 25, 1974, unless otherwise noted."
cfr_part: "64"
---

# 64.79 Inspection of pressure and vacuum relief device.

(a) The inspection of the pressure and vacuum relief device required in § 64.77(a) must include—

(1) Disassembling;

(2) A visual inspection for defective parts; and

(3) A test of the accuracy of the pressure setting.

(b) If the pressure and vacuum relief valve passes the inspection required in paragraph (a) of this section, the owner or his representative may attach to the device a metal tag containing the date of the inspection.