# 78.47-53 Automatic ventilation dampers.

(a) The manual operating positions for automatic fire dampers in ventilation ducts passing through main vertical zone bulkheads shall be identified by red day light-reflecting letters at least 
1/2 inch high “VENTILATION FIRE DAMPER.” In addition, the open and closed positions shall be similarly marked.

(b) [Reserved]