Skip to content
LexBuild

47 CFR § 15.225 - Operation within the band 13.110-14.010 MHz.

---
identifier: "/us/cfr/t47/s15.225"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "47 CFR § 15.225 - Operation within the band 13.110-14.010 MHz."
title_number: 47
title_name: "Telecommunication"
section_number: "15.225"
section_name: "Operation within the band 13.110-14.010 MHz."
chapter_name: "FEDERAL COMMUNICATIONS COMMISSION"
subchapter_number: "A"
subchapter_name: "GENERAL"
part_number: "15"
part_name: "RADIO FREQUENCY DEVICES"
positive_law: false
currency: "2026-03-24"
last_updated: "2026-03-24"
format_version: "1.1.0"
generator: "[email protected]"
authority: "47 U.S.C. 154, 302a, 303, 304, 307, 336, 544a, and 549."
regulatory_source: "54 FR 17714, Apr. 25, 1989, unless otherwise noted."
cfr_part: "15"
---

# 15.225 Operation within the band 13.110-14.010 MHz.

(a) The field strength of any emissions within the band 13.553-13.567 MHz shall not exceed 15,848 microvolts/meter at 30 meters.

(b) Within the bands 13.410-13.553 MHz and 13.567-13.710 MHz, the field strength of any emissions shall not exceed 334 microvolts/meter at 30 meters.

(c) Within the bands 13.110-13.410 MHz and 13.710-14.010 MHz the field strength of any emissions shall not exceed 106 microvolts/meter at 30 meters.

(d) The field strength of any emissions appearing outside of the 13.110-14.010 MHz band shall not exceed the general radiated emission limits in § 15.209.

(e) The frequency tolerance of the carrier signal shall be maintained within ±0.01% of the operating frequency over a temperature variation of −20 degrees to + 50 degrees C at normal supply voltage, and for a variation in the primary supply voltage from 85% to 115% of the rated supply voltage at a temperature of 20 degrees C. For battery operated equipment, the equipment tests shall be performed using a new battery.

(f) In the case of radio frequency powered tags designed to operate with a device authorized under this section, the tag may be approved with the device or be considered as a separate device subject to its own authorization. Powered tags approved with a device under a single application shall be labeled with the same identification number as the device.

[68 FR 68546, Dec. 9, 2003]