Skip to content
LexBuild

49 CFR § 192.279 - Copper pipe.

---
identifier: "/us/cfr/t49/s192.279"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "49 CFR § 192.279 - Copper pipe."
title_number: 49
title_name: "Transportation"
section_number: "192.279"
section_name: "Copper pipe."
chapter_name: "PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION"
subchapter_number: "D"
subchapter_name: "PIPELINE SAFETY"
part_number: "192"
part_name: "TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS"
positive_law: false
currency: "2026-04-05"
last_updated: "2026-04-05"
format_version: "1.1.0"
generator: "[email protected]"
authority: "30 U.S.C. 185(w)(3), 49 U.S.C. 5103, 60101  and 49 CFR 1.97."
regulatory_source: "35 FR 13257, Aug. 19, 1970, unless otherwise noted."
cfr_part: "192"
---

# 192.279 Copper pipe.

Copper pipe may not be threaded except for copper pipe that is used for joining screw fittings or valves, which may be threaded if the wall thickness is equivalent to the comparable size of Schedule 40 or heavier wall pipe listed in ASME B36.10M (incorporated by reference, *see* § 192.7).

[Amdt. 192-135, 89 FR 33281, Apr. 29, 2024]