Skip to content
LexBuild

49 CFR § 234.265 - Timing relays and timing devices.

---
identifier: "/us/cfr/t49/s234.265"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "49 CFR § 234.265 - Timing relays and timing devices."
title_number: 49
title_name: "Transportation"
section_number: "234.265"
section_name: "Timing relays and timing devices."
chapter_name: "FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION"
part_number: "234"
part_name: "GRADE CROSSING SAFETY"
positive_law: false
currency: "2026-03-24"
last_updated: "2026-03-24"
format_version: "1.1.0"
generator: "[email protected]"
authority: "49 U.S.C. 20103, 20107, 20152, 20160, 21301, 21304, 21311, 22907 note; 28 U.S.C. 2461 note; and 49 CFR 1.89."
regulatory_source: "61 FR 31806, June 20, 1996, unless otherwise noted."
cfr_part: "234"
---

# 234.265 Timing relays and timing devices.

Each timing relay and timing device shall be tested at least once every twelve months. The timing shall be maintained at not less than 90 percent nor more than 110 percent of the 41 predetermined time interval. The predetermined time interval shall be shown on the plans or marked on the timing relay or timing device. Timing devices which perform internal functions associated with motion detectors, motion sensors, and grade crossing predictors are not subject to the requirements of this section.