Skip to content
LexBuild

49 CFR § 236.314 - Electric lock for hand-operated switch or derail.

---
identifier: "/us/cfr/t49/s236.314"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "49 CFR § 236.314 - Electric lock for hand-operated switch or derail."
title_number: 49
title_name: "Transportation"
section_number: "236.314"
section_name: "Electric lock for hand-operated switch or derail."
chapter_name: "FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION"
part_number: "236"
part_name: "RULES, STANDARDS, AND INSTRUCTIONS GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES"
positive_law: false
currency: "2026-03-24"
last_updated: "2026-03-24"
format_version: "1.1.0"
generator: "[email protected]"
authority: "49 U.S.C. 20102-20103, 20107, 20133, 20141, 20157, 20301-20303, 20306, 20501-20505, 20701-20703, 21301-21302, 21304; 28 U.S.C. 2461 note; and 49 CFR 1.89."
regulatory_source: "33 FR 19684, Dec. 25, 1968, unless otherwise noted."
cfr_part: "236"
---

# 236.314 Electric lock for hand-operated switch or derail.

Electric lock shall be provided for each hand-operated switch or derail within interlocking limits, except where train movements are made at not exceeding 20 miles per hour. At manually operated interlocking it shall be controlled by operator of the machine and shall be unlocked only after signals governing movements over such switch or derail display aspects indicating stop. Approach or time locking shall be provided.