Skip to content
LexBuild

49 CFR § 236.6 - Hand-operated switch equipped with switch circuit controller.

---
identifier: "/us/cfr/t49/s236.6"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "49 CFR § 236.6 - Hand-operated switch equipped with switch circuit controller."
title_number: 49
title_name: "Transportation"
section_number: "236.6"
section_name: "Hand-operated switch equipped with switch circuit controller."
chapter_name: "FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION"
part_number: "236"
part_name: "RULES, STANDARDS, AND INSTRUCTIONS GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES"
positive_law: false
currency: "2026-03-24"
last_updated: "2026-03-24"
format_version: "1.1.0"
generator: "[email protected]"
authority: "49 U.S.C. 20102-20103, 20107, 20133, 20141, 20157, 20301-20303, 20306, 20501-20505, 20701-20703, 21301-21302, 21304; 28 U.S.C. 2461 note; and 49 CFR 1.89."
regulatory_source: "33 FR 19684, Dec. 25, 1968, unless otherwise noted."
cfr_part: "236"
---

# 236.6 Hand-operated switch equipped with switch circuit controller.

Hand-operated switch equipped with switch circuit controller connected to the point, or with facing-point lock and circuit controller, shall be so maintained that when point is open one-fourth inch or more on facing-point switch and three-eights inch or more on trailing-point switch, track or control circuits will be opened or shunted or both, and if equipped with facing-point lock with circuit controller, switch cannot be locked. On such hand-operated switch, switch circuit controllers, facing-point locks, switch-and-lock movements, and their connections shall be securely fastened in place, and contacts maintained with an opening of not less than one-sixteenth inch when open.