# [AMENDED]
**Correction**
In proposed rule document 2013-28776 appearing on pages 73589-73681 in the issue of Friday, December 6, 2013, make the following corrections:
1. On page 73594, Table I.5 should appear as set forth below:
| Motor horsepower/standard kilowatt equivalent | Nominal full load efficiency (%) | 4 Pole | Enclosed | Open | 6 Pole | Enclosed | Open | 8 Pole | Enclosed | Open |
| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |
| 1/.75 | 85.5 | 85.5 | 82.5 | 82.5 | 75.5 | 75.5 | | | | |
| 1.5/1.1 | 86.5 | 86.5 | 87.5 | 86.5 | 78.5 | 77.0 | | | | |
| 2/1.5 | 86.5 | 86.5 | 88.5 | 87.5 | 84.0 | 86.5 | | | | |
| 3/2.2 | 89.5 | 89.5 | 89.5 | 88.5 | 85.5 | 87.5 | | | | |
| 5/3.7 | 89.5 | 89.5 | 89.5 | 89.5 | 86.5 | 88.5 | | | | |
| 7.5/5.5 | 91.7 | 91.0 | 91.0 | 90.2 | 86.5 | 89.5 | | | | |
| 10/7.5 | 91.7 | 91.7 | 91.0 | 91.7 | 89.5 | 90.2 | | | | |
| 15/11 | 92.4 | 93.0 | 91.7 | 91.7 | 89.5 | 90.2 | | | | |
| 20/15 | 93.0 | 93.0 | 91.7 | 92.4 | 90.2 | 91.0 | | | | |
| 25/18.5 | 93.6 | 93.6 | 93.0 | 93.0 | 90.2 | 91.0 | | | | |
| 30/22 | 93.6 | 94.1 | 93.0 | 93.6 | 91.7 | 91.7 | | | | |
2. On page 73627, Tables IV.10 and IV.11 should appear as follows:
| Representative unit | EL 0 | EL 1 | EL 2 | EL 3 |
| --- | --- | --- | --- | --- |
| 5 hp | 87.5 | 89.5 | 90.2 | 91.0 |
| 30 hp | 92.4 | 93.6 | 94.1 | 94.5 |
| 75 hp | 94.1 | 95.4 | 95.8 | 96.2 |
| Representative unit | EL 1 | EL 2 | EL 3 |
| --- | --- | --- | --- |
| 5 hp | 87.5 | 89.5 | 91.0 |
| 50 hp | 92.4 | 93.6 | 94.5 |
3. On page 73634, in Table IV.14, In the second row, in the second column “1.61” Should read “51.61”.
| Representative unit | Per unit adder for 1 band above NEMA | Per unit adder for 2 bands above NEMA |
| --- | --- | --- |
| 5 HP, Design B | $11.06 | $17.36 |
| 30 HP, Design B | $32.89 | $51.61 |
| 75 HP, Design B | $66.18 | $103.86 |
| 5 HP, Design C | $10.68 | $16.75 |
| 50 HP, Design C | $60.59 | $95.08 |
§ 431.25
4. On page 73679, in § 431.25(d), Table 4 should appear as set forth below:
| Motor horsepower/standard kilowatt equivalent | Nominal full-load efficiency | Open motors (number of poles) | 8 | 6 | 4 | 2 | Enclosed motors (number of poles) | 8 | 6 | 4 | 2 |
| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |
| 250/186 | 94.5 | 95.4 | 95.4 | 94.5 | 94.5 | 95.0 | 95.0 | 95.4 | | | |
| 300/224 | | 95.4 | 95.4 | 95.0 | | 95.0 | 95.4 | 95.4 | | | |
| 350/261 | | 95.4 | 95.4 | 95.0 | | 95.0 | 95.4 | 95.4 | | | |
| 400/298 | | | 95.4 | 95.4 | | | 95.4 | 95.4 | | | |
| 450/336 | | | 95.8 | 95.8 | | | 95.4 | 95.4 | | | |
| 500/373 | | | 95.8 | 95.8 | | | 95.8 | 95.4 | | | |