Skip to content
LexBuild

Energy Conservation Program: Energy Conservation Standards for Commercial and Industrial Electric Motors

---
identifier: "/us/fr/C1-2013-28776"
source: "fr"
legal_status: "authoritative_unofficial"
title: "Energy Conservation Program: Energy Conservation Standards for Commercial and Industrial Electric Motors"
title_number: 0
title_name: "Federal Register"
section_number: "C1-2013-28776"
section_name: "Energy Conservation Program: Energy Conservation Standards for Commercial and Industrial Electric Motors"
positive_law: false
currency: "2014-02-14"
last_updated: "2014-02-14"
format_version: "1.1.0"
generator: "[email protected]"
agency: "Energy Department"
document_number: "C1-2013-28776"
document_type: "proposed_rule"
publication_date: "2014-02-14"
agencies:
  - "Energy Department"
cfr_references:
  - "10 CFR Part 431"
rin: "1904-AC28"
fr_citation: "79 FR 8903"
fr_volume: 79
docket_ids:
  - "Docket Number EERE-2010-BT-STD-0027"
---

#  [AMENDED]

**Correction**

In proposed rule document 2013-28776 appearing on pages 73589-73681 in the issue of Friday, December 6, 2013, make the following corrections:

1. On page 73594, Table I.5 should appear as set forth below:

| Motor horsepower/standard kilowatt equivalent | Nominal full load efficiency (%) | 4 Pole | Enclosed | Open | 6 Pole | Enclosed | Open | 8 Pole | Enclosed | Open |
| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |
| 1/.75 | 85.5 | 85.5 | 82.5 | 82.5 | 75.5 | 75.5 |  |  |  |  |
| 1.5/1.1 | 86.5 | 86.5 | 87.5 | 86.5 | 78.5 | 77.0 |  |  |  |  |
| 2/1.5 | 86.5 | 86.5 | 88.5 | 87.5 | 84.0 | 86.5 |  |  |  |  |
| 3/2.2 | 89.5 | 89.5 | 89.5 | 88.5 | 85.5 | 87.5 |  |  |  |  |
| 5/3.7 | 89.5 | 89.5 | 89.5 | 89.5 | 86.5 | 88.5 |  |  |  |  |
| 7.5/5.5 | 91.7 | 91.0 | 91.0 | 90.2 | 86.5 | 89.5 |  |  |  |  |
| 10/7.5 | 91.7 | 91.7 | 91.0 | 91.7 | 89.5 | 90.2 |  |  |  |  |
| 15/11 | 92.4 | 93.0 | 91.7 | 91.7 | 89.5 | 90.2 |  |  |  |  |
| 20/15 | 93.0 | 93.0 | 91.7 | 92.4 | 90.2 | 91.0 |  |  |  |  |
| 25/18.5 | 93.6 | 93.6 | 93.0 | 93.0 | 90.2 | 91.0 |  |  |  |  |
| 30/22 | 93.6 | 94.1 | 93.0 | 93.6 | 91.7 | 91.7 |  |  |  |  |

2. On page 73627, Tables IV.10 and IV.11 should appear as follows:

| Representative unit | EL 0 | EL 1 | EL 2 | EL 3 |
| --- | --- | --- | --- | --- |
| 5 hp | 87.5 | 89.5 | 90.2 | 91.0 |
| 30 hp | 92.4 | 93.6 | 94.1 | 94.5 |
| 75 hp | 94.1 | 95.4 | 95.8 | 96.2 |

| Representative unit | EL 1 | EL 2 | EL 3 |
| --- | --- | --- | --- |
| 5 hp | 87.5 | 89.5 | 91.0 |
| 50 hp | 92.4 | 93.6 | 94.5 |

3. On page 73634, in Table IV.14, In the second row, in the second column “1.61” Should read “51.61”.

| Representative unit | Per unit adder for 1 band above NEMA | Per unit adder for 2 bands above NEMA |
| --- | --- | --- |
| 5 HP, Design B | $11.06 | $17.36 |
| 30 HP, Design B | $32.89 | $51.61 |
| 75 HP, Design B | $66.18 | $103.86 |
| 5 HP, Design C | $10.68 | $16.75 |
| 50 HP, Design C | $60.59 | $95.08 |

§ 431.25

4. On page 73679, in § 431.25(d), Table 4 should appear as set forth below:

| Motor horsepower/standard kilowatt equivalent | Nominal full-load efficiency | Open motors (number of poles) | 8 | 6 | 4 | 2 | Enclosed motors (number of poles) | 8 | 6 | 4 | 2 |
| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |
| 250/186 | 94.5 | 95.4 | 95.4 | 94.5 | 94.5 | 95.0 | 95.0 | 95.4 |  |  |  |
| 300/224 |  | 95.4 | 95.4 | 95.0 |  | 95.0 | 95.4 | 95.4 |  |  |  |
| 350/261 |  | 95.4 | 95.4 | 95.0 |  | 95.0 | 95.4 | 95.4 |  |  |  |
| 400/298 |  |  | 95.4 | 95.4 |  |  | 95.4 | 95.4 |  |  |  |
| 450/336 |  |  | 95.8 | 95.8 |  |  | 95.4 | 95.4 |  |  |  |
| 500/373 |  |  | 95.8 | 95.8 |  |  | 95.8 | 95.4 |  |  |  |