AC17 air conditioning efficiency test procedure. [Corrected]
---
identifier: "/us/fr/C1-2014-06954"
source: "fr"
legal_status: "authoritative_unofficial"
title: "AC17 air conditioning efficiency test procedure. [Corrected]"
title_number: 0
title_name: "Federal Register"
section_number: "C1-2014-06954"
section_name: "AC17 air conditioning efficiency test procedure. [Corrected]"
positive_law: false
currency: "2014-06-28"
last_updated: "2014-06-28"
format_version: "1.1.0"
generator: "[email protected]"
agency: "ENVIRONMENTAL PROTECTION AGENCY"
document_number: "C1-2014-06954"
document_type: "rule"
publication_date: "2014-06-28"
agencies:
- "ENVIRONMENTAL PROTECTION AGENCY"
cfr_references:
- "40 CFR Parts 79, 80, 85, 86, 600, 1036, 1037, 1039, 1042, 1048, 1054, 1065, and 1066"
rin: "2060-AQ86"
---
# AC17 air conditioning efficiency test procedure. [Corrected]
**Correction**
In rule document 2014-06954, appearing on pages 23414-23886, in the issue of Monday, April 28, 2014, make the following corrections:
**40 CFR Part 86**
§ 86.113-94
On page 23695 make the following correction:
The first table on page 23695 is corrected as set forth below.
| Property | Unit | Type 2-D | Reference procedure |
| --- | --- | --- | --- |
| (i) Cetane Number | | 40-50 | ASTM D613 |
| (ii) Cetane Index | | 40-50 | ASTM D976 |
| (iii) Distillation range: | | | |
| (A) IBP | | 340-400 (171.1-204.4) | |
| (B) 10 pct. point | | 400-460 (204.4-237.8) | |
| (C) 50 pct. point | °F (°C) | 470-540 (243.3-282.2) | STM D86 |
| (D) 90 pct. point | | 560-630 (293.3-332.2) | |
| (E) EP | | 610-690 (321.1-365.6) | |
| (iv) Gravity | °API | 32-37 | ASTM D4052 |
| (v) Total sulfur | ppm | 7-15 | ASTM D2622 |
| (vi) Hydrocarbon composition: Aromatics, minimum (Remainder shall be paraffins, naphthenes, and olefins) | pct | 27 | ASTM D5186 |
| (vii) Flashpoint, min | °F (°C) | 130 (54.4) | ASTM D93 |
| (viii) Viscosity | centistokes | 2.0-3.2 | ASTM D445 |
**40 CFR Part 1065**
§ 1065.845
On page 23813 make the following correction:
The table heading for the table titled “Table 1 of § 1065.845” is corrected to read as set forth below.
**Table 1 of § 1065.845—Default Values for THC FID Response Factor Relative to Propane on a C
1
-Equivalent Basis**
**40 CFR Part 1066**
§ 1066.845
On page 23881 make the following correction:
The equation in the first column is corrected to read as set forth below.