# 27.1391 Minimum intensities in the horizontal plane of forward and rear position lights.

Each position light intensity must equal or exceed the applicable values in the following table:

| Dihedral angle (light included) | Angle from right or left of longitudinal axis, measured from dead ahead | Intensity (candles) |
| --- | --- | --- |
| and  (forward red and green) | 10° to 10°10° to 20°20° to 110° | 40305 |
| (rear white) | 110° to 180° | 20 |