Skip to content
LexBuild

46 CFR § 108.201 - Size of sleeping spaces.

---
identifier: "/us/cfr/t46/s108.201"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "46 CFR § 108.201 - Size of sleeping spaces."
title_number: 46
title_name: "Shipping"
section_number: "108.201"
section_name: "Size of sleeping spaces."
chapter_name: "COAST GUARD, DEPARTMENT OF HOMELAND SECURITY"
subchapter_number: "I-A"
subchapter_name: "A—MOBILE OFFSHORE DRILLING UNITS"
part_number: "108"
part_name: "DESIGN AND EQUIPMENT"
positive_law: false
currency: "2026-04-05"
last_updated: "2026-04-05"
format_version: "1.1.0"
generator: "[email protected]"
authority: "43 U.S.C. 1333; 46 U.S.C. 3102, 3306; DHS Delegation No. 00170.1, Revision No. 01.4."
regulatory_source: "CGD 73-251, 43 FR 56808, Dec. 4, 1978, unless otherwise noted."
cfr_part: "108"
---

# 108.201 Size of sleeping spaces.

(a) No sleeping space may berth more than four persons, except that a sleeping space for personnel not regularly employed on a unit may berth up to six persons if the space meets § 108.199 and berthing of six persons in that space is authorized by the Commandant (CG-OES).

(b) Without deducting any equipment used by the occupants, each sleeping space must have for each occupant—

(1) 2.8 square meters (approximately 30 square feet) of deck area; and

(2) 6 cubic meters (approximately 210 cubic feet) of volume.

(c) Each sleeping space must have at least 191 centimeters (approximately 6 feet 3 inches) of headroom over clear deck areas.

[CGD 73-251, 43 FR 56808, Dec. 4, 1978, as amended by CGD 82-063b, 48 FR 4781, Feb. 3, 1983; CGD 95-072, 60 FR 50465, Sept. 29, 1995; CGD 96-041, 61 FR 50730, Sept. 27, 1996; USCG-2009-0702, 74 FR 49233, Sept. 25, 2009; USCG-2012-0832, 77 FR 59781, Oct. 1, 2012]