Title 46, Part 108 — Design and Equipment
173 sections
Section 108.101
Incorporation by reference.
Section 108.102
Preemptive effect.
Section 108.103
Equipment not required on a unit.
Section 108.105
Substitutes for required fittings, material, apparatus, equipment, arrangements, calculations, and tests.
Section 108.109
Classification society standards.
Section 108.113
Structural standards.
Section 108.114
Appliances for watertight and weathertight integrity.
Section 108.123
Isolation of combustible material.
Section 108.127
Storage lockers for combustibles.
Section 108.131
Definitions.
Section 108.133
Hull superstructure, structural bulkheads, decks, and deckhouses.
Section 108.135
Boundary bulkheads, decks of galleys, and combustible material lockers.
Section 108.137
Bulkhead and deck separations of accommodation spaces.
Section 108.139
Boundary bulkheads and decks of a space containing emergency power.
Section 108.141
Boundary bulkheads and decks between the emergency power source and service generators.
Section 108.143
Accommodation space.
Section 108.145
Hatches and tonnage openings.
Section 108.147
Certain paints prohibited.
Section 108.151
Two means required.
Section 108.153
Location of means of escape.
Section 108.155
Restrictions on means of escape utilized.
Section 108.157
Locked doors.
Section 108.159
Stairways and exterior inclined ladders.
Section 108.160
Vertical ladders.
Section 108.161
Dead end corridors.
Section 108.165
Access to lifeboats and liferafts.
Section 108.167
Weather deck ladders.
Section 108.170
Definitions.
Section 108.171
Class I, Division 1 locations.
Section 108.173
Class I, Division 2 locations.
Section 108.175
Contiguous locations.
Section 108.177
Electrical equipment in classified locations.
Section 108.181
Ventilation for enclosed spaces.
Section 108.185
Ventilation for enclosed classified locations.
Section 108.187
Ventilation for brush type electric motors in classified spaces.
Section 108.193
Restrictions.
Section 108.195
Location of accommodation spaces.
Section 108.197
Construction of accommodation spaces.
Section 108.199
Arrangement of sleeping spaces.
Section 108.201
Size of sleeping spaces.
Section 108.203
Berths and lockers.
Section 108.205
Wash spaces; toilet spaces; and shower spaces.
Section 108.207
Messrooms.
Section 108.209
Hospital spaces.
Section 108.210
Hospital space not required.
Section 108.211
Miscellaneous accommodation spaces.
Section 108.213
Heating requirements.
Section 108.215
Insect screens.
Section 108.217
Guardrails and bulwarks.
Section 108.219
Guardrails.
Section 108.221
Storm rails.
Section 108.223
Guards on exposed equipment.
Section 108.231
Application.
Section 108.233
Location and size.
Section 108.235
Construction.
Section 108.237
Fuel storage facilities.
Section 108.239
Fuel transfer equipment.
Section 108.241
Visual aids.
Section 108.301
Stability.
Section 108.401
Fire main system.
Section 108.403
Fire extinguishing systems: General.
Section 108.403a
Fire extinguishing systems: Non-vital services.
Section 108.404
Selection of fire detection system.
Section 108.405
Fire detection system.
Section 108.407
Detectors for electric fire detection system.
Section 108.409
Location and spacing of tubing in pneumatic fire detection system.
Section 108.411
Smoke detection system.
Section 108.413
Fusible element fire detection system.
Section 108.415
Fire pump: General.
Section 108.417
Fire pump components and associated equipment.
Section 108.419
Fire main capacity.
Section 108.421
Location of fire pumps and associated equipment.
Section 108.423
Fire hydrants and associated equipment.
Section 108.425
Fire hoses and associated equipment.
Section 108.427
International shore connection.
Section 108.429
Fire main system protection.
Section 108.430
General.
Section 108.431
Carbon dioxide systems: General.
Section 108.433
Quantity of CO: General.
Section 108.437
Pipe sizes and discharge rates for enclosed ventilation systems for rotating electrical equipment.
Section 108.439
Quantity of CO for protection of spaces.
Section 108.441
Piping and discharge rates for CO systems.
Section 108.443
Controls and valves.
Section 108.444
Lockout valves.
Section 108.445
Alarm and means of escape.
Section 108.446
Odorizing units.
Section 108.447
Piping.
Section 108.449
Piping tests.
Section 108.451
CO storage.
Section 108.453
Discharge outlets.
Section 108.455
Enclosure openings.
Section 108.457
Pressure release.
Section 108.458
General.
Section 108.459
Number and location of outlets.
Section 108.461
Coamings.
Section 108.463
Foam rate: Protein.
Section 108.467
Water supply.
Section 108.469
Quantity of foam producing materials.
Section 108.471
Water pump.
Section 108.473
Foam system components.
Section 108.474
Aqueous film forming foam systems.
Section 108.475
Piping.
Section 108.477
Fire hydrants.
Section 108.486
Helicopter decks.
Section 108.487
Helicopter deck fueling operations.
Section 108.489
Helicopter fueling facilities.
Section 108.491
General.
Section 108.493
Location.
Section 108.495
Locations and number of fire extinguishers required.
Section 108.496
Semi-portable fire extinguishers.
Section 108.497
Fireman's outfits.
Section 108.499
Fire axes.
Section 108.500
General.
Section 108.503
Relationship to international standards.
Section 108.510
Application.
Section 108.515
Requirements for units built before October 1, 1996.
Section 108.520
Type of survival craft.
Section 108.525
Survival craft number and arrangement.
Section 108.530
Stowage of survival craft.
Section 108.540
Survival craft muster and embarkation arrangements.
Section 108.545
Marine evacuation system launching arrangements.
Section 108.550
Survival craft launching and recovery arrangements: General.
Section 108.553
Survival craft launching and recovery arrangements using falls and a winch.
Section 108.555
Lifeboat launching and recovery arrangements.
Section 108.557
Free-fall lifeboat launching and recovery arrangements.
Section 108.560
Rescue boats.
Section 108.565
Stowage of rescue boats.
Section 108.570
Rescue boat embarkation, launching and recovery arrangements.
Section 108.575
Survival craft and rescue boat equipment.
Section 108.580
Personal lifesaving appliances.
Section 108.595
Communications.
Section 108.597
Line-throwing appliance.
Section 108.601
Crane design.
Section 108.621
Equipment markings: General.
Section 108.623
General alarm bell switch.
Section 108.625
General alarm bell.
Section 108.626
Carbon dioxide warning signs.
Section 108.627
Carbon dioxide and clean agent alarms.
Section 108.629
Fire extinguishing system branch line valve.
Section 108.631
Fixed fire extinguishing system controls.
Section 108.633
Fire stations.
Section 108.635
Self-contained breathing apparatus.
Section 108.636
Work vests.
Section 108.637
Hand portable fire extinguishers.
Section 108.639
Emergency lights.
Section 108.641
Instructions for changing steering gear.
Section 108.643
Rudder orders.
Section 108.645
Markings on lifesaving appliances.
Section 108.646
Marking of stowage locations.
Section 108.647
Inflatable liferafts.
Section 108.649
Lifejackets, immersion suits, and lifebuoys.
Section 108.650
Epirbs and Sarts.
Section 108.651
Portable magazine chests.
Section 108.653
Helicopter facilities.
Section 108.655
Operating instructions.
Section 108.657
Unit markings.
Section 108.659
Lifesaving signal instructions.
Section 108.661
Unit markings: Draft marks.
Section 108.663
Unit markings: Load line.
Section 108.665
Appliances for watertight integrity.
Section 108.697
Buoyant work vests.
Section 108.699
Substitution of life preservers.
Section 108.701
Sounding equipment.
Section 108.703
Self-contained breathing apparatus.
Section 108.705
Anchors, chains, wire rope, and hawsers.
Section 108.707
First aid kit.
Section 108.709
Litter.
Section 108.713
International Code of Signals.
Section 108.715
Magnetic compass and gyrocompass.
Section 108.717
Radar.
Section 108.719
Pilot boarding equipment.
Section 108.801
Navigation bridge visibility.
Section 108.901
Muster list and emergency instructions.