Skip to content
LexBuild

46 CFR § 108.597 - Line-throwing appliance.

---
identifier: "/us/cfr/t46/s108.597"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "46 CFR § 108.597 - Line-throwing appliance."
title_number: 46
title_name: "Shipping"
section_number: "108.597"
section_name: "Line-throwing appliance."
chapter_name: "COAST GUARD, DEPARTMENT OF HOMELAND SECURITY"
subchapter_number: "I-A"
subchapter_name: "A—MOBILE OFFSHORE DRILLING UNITS"
part_number: "108"
part_name: "DESIGN AND EQUIPMENT"
positive_law: false
currency: "2026-04-05"
last_updated: "2026-04-05"
format_version: "1.1.0"
generator: "[email protected]"
authority: "43 U.S.C. 1333; 46 U.S.C. 3102, 3306; DHS Delegation No. 00170.1, Revision No. 01.4."
regulatory_source: "CGD 73-251, 43 FR 56808, Dec. 4, 1978, unless otherwise noted."
cfr_part: "108"
---

# 108.597 Line-throwing appliance.

(a) *General.* Each unit in international service must have a line-throwing appliance that is approved under approval series 160.040. Each unit not in international service must carry a line-throwing appliance approved under either approval series 160.040 or 160.031.

(b) *Stowage.* The line-throwing appliance and its equipment must be readily accessible for use.

(c) *Additional equipment.* Each unit must carry the following equipment for the line-throwing appliance:

(1) The equipment on the list provided by the manufacturer with the approved appliance; and

(2) An auxiliary line that—

(i) Has a breaking strength of at least 40 kiloNewtons (9,000 pounds-force);

(ii) Is, if synthetic, a dark color or certified by the manufacturer to be resistant to deterioration from ultraviolet light; and

(iii) Is—

(A) At least 450 meters (1,500 feet) long, if the line-throwing appliance is approved under approval series 160.040; or

(B) At least 150 meters (500 feet) long, if the line-throwing appliance is approved under approval series 160.031.