Skip to content
LexBuild

46 CFR § 162.050-19 - Oil content meter and bilge alarm test rig.

---
identifier: "/us/cfr/t46/s162.050-19"
source: "ecfr"
legal_status: "authoritative_unofficial"
title: "46 CFR § 162.050-19 - Oil content meter and bilge alarm test rig."
title_number: 46
title_name: "Shipping"
section_number: "162.050-19"
section_name: "Oil content meter and bilge alarm test rig."
chapter_name: "COAST GUARD, DEPARTMENT OF HOMELAND SECURITY"
subchapter_number: "Q"
subchapter_name: "EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL"
part_number: "162"
part_name: "ENGINEERING EQUIPMENT"
positive_law: false
currency: "2026-03-24"
last_updated: "2026-03-24"
format_version: "1.1.0"
generator: "[email protected]"
authority: "33 U.S.C. 1321(j), 1903; 46 U.S.C. 3306, 3703, 4104, 4302; E.O. 12234, 45 FR 58801, 3 CFR, 1980 Comp., p. 277; E.O. 12777, 56 FR 54757, 3 CFR, 1991 Comp., p. 351; DHS Delegation 00170.1, Revision No. 01.4."
cfr_part: "162"
---

# 162.050-19 Oil content meter and bilge alarm test rig.

(a) This section contains requirements for test rigs used in approval testing of oil content meters and meter. A typical test rig is described in Figure 162.050-19. The mixture pipe shown in Figure 162.050-19 is the portion of test rig piping between the oil injection point and the meter or bilge alarm piping.

(b) Each sample point on a test rig must be of the type described in Figure 162.050-17(e) and must be in a vertical portion of the test rig piping.

(c) Each test rig must have a centrifugal pump that is designed to operate at 1,000 revolutions per minute or more.

(d) The mixture pipe on a test rig must have a uniform inside diameter.

****FIGURE 162.050-19—MONITOR AND BILGE ALARM TEST RIG

[CGD 76-088a, 44 FR 53359, Sept. 13, 1979, as amended by USCG-2004-18939, 74 FR 3385, Jan. 16, 2009]