Title 24, Part 3285 — Model Manufactured Home Installation Standards
63 sections
Section 3285.1
Administration.
Section 3285.2
Manufacturer installation instructions.
Section 3285.3
Alterations during initial installation.
Section 3285.4
Incorporation by reference (IBR).
Section 3285.5
Definitions.
Section 3285.6
Final leveling of manufactured home.
Section 3285.101
Fire separation.
Section 3285.102
Installation of manufactured homes in flood hazard areas.
Section 3285.103
Site suitability with design zone maps.
Section 3285.104
Moving manufactured home to location.
Section 3285.105
Permits, other alterations, and on-site structures.
Section 3285.201
Soil conditions.
Section 3285.202
Soil classifications and bearing capacity.
Section 3285.203
Site Drainage.
Section 3285.204
Ground moisture control.
Section 3285.301
General.
Section 3285.302
Flood hazard areas.
Section 3285.303
Piers.
Section 3285.304
Pier configuration.
Section 3285.305
Clearance under homes.
Section 3285.306
Design procedures for concrete block piers.
Section 3285.307
Perimeter support piers.
Section 3285.308
Manufactured piers.
Section 3285.309
[Reserved]
Section 3285.310
Pier location and spacing.
Section 3285.311
Required perimeter supports.
Section 3285.312
Footings.
Section 3285.313
Combination systems.
Section 3285.314
[Reserved]
Section 3285.315
Special snow load conditions.
Section 3285.401
Anchoring instructions.
Section 3285.402
Ground anchor installations.
Section 3285.403
Sidewall, over-the-roof, mate-line, and shear wall straps.
Section 3285.404
Severe climatic conditions.
Section 3285.405
Severe wind zones.
Section 3285.406
Flood hazard areas.
Section 3285.501
Home installation manual supplements.
Section 3285.502
Expanding rooms.
Section 3285.503
Optional appliances.
Section 3285.504
Skirting.
Section 3285.505
Crawlspace ventilation.
Section 3285.506
Testing and certification for fire sprinkler systems.
Section 3285.601
Field assembly.
Section 3285.602
Utility connections.
Section 3285.603
Water supply.
Section 3285.604
Drainage system.
Section 3285.605
Fuel supply system.
Section 3285.606
Ductwork connections.
Section 3285.701
Electrical crossovers.
Section 3285.702
Miscellaneous lights and fixtures.
Section 3285.703
Smoke alarms.
Section 3285.704
Telephone and cable TV.
Section 3285.801
Exterior close-up.
Section 3285.802
Structural interconnection of multi-section homes.
Section 3285.803
Interior close-up.
Section 3285.804
Bottom board repair.
Section 3285.901
General.
Section 3285.902
Moving manufactured home to location.
Section 3285.903
Permits, alterations, and on-site structures.
Section 3285.904
Utility system connections.
Section 3285.905
Heating oil systems.
Section 3285.906
Telephone and cable TV.
Section 3285.907
Manufacturer additions to installation instructions.